0
RESEARCH PAPERS

Optimal Operation of a Cogeneration Plant in Combination With Electric Heat Pumps

[+] Author and Article Information
K. Ito, T. Shiba, R. Yokoyama

Department of Energy Systems Engineering, University of Osaka Prefecture, 1-1, Gakuen-cho, Sakai, Osaka 593, Japan

J. Energy Resour. Technol 116(1), 56-64 (Mar 01, 1994) (9 pages) doi:10.1115/1.2906010 History: Received February 17, 1993; Revised August 30, 1993; Online April 16, 2008

Abstract

An operational problem is discussed for a gas turbine cogeneration plant in combination with a heat pump/thermal storage system that utilizes time-of-use pricing of the electrical utility. An optimal planning method is presented by which the operational policy of constituent equipment is determined so as to minimize the daily operational cost. An algorithm is proposed to solve this optimization problem efficiently by combining the dynamic programming method with the mixed-integer programming one. A case study is carried out to investigate the effect of introducing a heat pump system into a cogeneration plant.