0
TECHNICAL PAPERS

Effects of Jet Reynolds Number on the Performance of Axisymmetric and Nonaxisymmetric Gas Burner Flames

[+] Author and Article Information
Azfar Kamal

GE Appliances, Louisville, KY 40025e-mail: azfar.kamal@appl.ge.com

S. R. Gollahalli

School of Aerospace and Mechanical Engineering, University of Oklahoma, Norman, OK 73019 e-mail: gollahal@ou.edu

J. Energy Resour. Technol 123(2), 167-172 (Nov 10, 2000) (6 pages) doi:10.1115/1.1367858 History: Received July 31, 1999; Revised November 10, 2000
Copyright © 2001 by ASME
Your Session has timed out. Please sign back in to continue.

References

Figures

Grahic Jump Location
Effect of burner exit Reynolds number on the air entrainment into the flames of circular and elliptic burners (NE=no. of moles of air into elliptic burner flames, NC=no. of moles of air into circular burner flame). Number following E indicates the burner aspect ratio.
Grahic Jump Location
Emission indices of NO, NO2, and CO from the circular and elliptic burner flames at three burner exit Reynolds numbers; left Re=9400; middle Re=14,000, right Re=19,000 (EIE=emission index in the elliptic burner flames, EIC=emission index in the circular burner flame; at Re=9400EINO=12.7 ng/J,EINO2=4.95 ng/J,EICO=96.8 ng/J; at Re=14,000EINO=15.6 ng/J,EINO2=0.95 ng/J,EICO=46.5 ng/J; at Re=19,000EINO=16.2 ng/J,EINO2=0.62 ng/J,EICO=37.7 ng/J).
Grahic Jump Location
Effect of burner exit Reynolds number on radiative fraction from circular and elliptic burner flames
Grahic Jump Location
Effect of burner exit Reynolds number on visible length of flames from circular and elliptic burners
Grahic Jump Location
Effects of burner exit Reynolds number on temperature profiles in the near-nozzle region (X/D=5) of circular and elliptic burner flames
Grahic Jump Location
Effect of burner exit Reynolds number on temperature profiles in the far-nozzle region (X/D=130) of circular and elliptic burner flames
Grahic Jump Location
Effects of burner exit Reynolds number on soot concentration in flames from circular and elliptic burners
Grahic Jump Location
(a) Experimental arrangement. (b) Dimensions of the burner tubes: circular burner C(D=5.2 mm); elliptic E1 (2a=7.2 mm,2b=3.7 mm); elliptic E3 (2a=9 mm,2b=3 mm); elliptic E4 (2a=10.4 mm,2b=2.6 mm).

Tables

Errata

Discussions

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related Journal Articles
Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us: