0
TECHNICAL PAPERS

Performance Evaluation of Coriolis Mass Flowmeters

[+] Author and Article Information
Mohammed N. Al-Khamis

Colorado School of Mines, Golden, CO 80401

Ali A. Al-Nojaim

SPE, Saudi Aramco, Ras Tanura, Saudi Arabia 31311

Muhammad A. Al-Marhoun

SPE, KFUPM, Dhahran, Saudi Arabia 31261

J. Energy Resour. Technol 124(2), 90-94 (May 28, 2002) (5 pages) doi:10.1115/1.1467644 History: Received September 18, 2000; Revised September 06, 2001; Online May 28, 2002
Copyright © 2002 by ASME
Your Session has timed out. Please sign back in to continue.

References

Golike, Curd, Cardellini, Dave, and Albuja, Fernando, “WellComp Multiphase Flowmeter,” Oxy Field Experience with Replacement of Traditional Well Test Separators. The North Sea Flow Measurement Workshop, October 1995.
Liu, K. T., and Kouba, G. E., “Coriolis-Based Net Oil Computers Gain Acceptance at the Wellhead,” Oil & Gas Journal, June 27, 1994.
Blickley, G. J., “Mass Flowmeters Shape Up,” Control Engineering, December 1994.
Henry, M., “Self-Validation Improves Coriolis Flowmeter,” Control Engineering, May 1995.
Liu, K. T., and Revus, David E., “Net-Oil Computer Improves Water-Cut Determination,” Oil & Gas Journal, December 19, 1988.
Blickley, G. J., “Coriolis for the Masses,” Control Engineering, June 1995.
Al-Taweel, A. B., Barlow, S. G., and Aggour, M. A., “Development and testing of Multiphase Metering Unit Utilizing Coriolis Meters,” SPE 38785, SPE Conference, San Antonio, Texas, 5-8 October 1997.
Al-Mubarak, A. M., “A New Method In Calculating Water Cut and Oil and Water Volumes Using Coriolis Meter,” SPE 38786, SPE Conference, San Antonio, Texas, 5-8 October 1997.
Micro Motion, Inc. of Fisher-Rosemount. Product Catalog, 1997.
Endress+Hauser, Promass 63 Mass Flow Measuring System. Operating Manual, 1997.

Figures

Grahic Jump Location
WellComp multiphase test unit sketch
Grahic Jump Location
Coriolis mass flowmeter tube configurations and geometry
Grahic Jump Location
U-tube coriolis mass flowmeter test results
Grahic Jump Location
Pressure versus rate curve of a well with testing problem
Grahic Jump Location
Modified U-tube coriolis mass flowmeter test results
Grahic Jump Location
Straight tube coriolis mass flowmeter test results

Tables

Errata

Discussions

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related Journal Articles
Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In