The development of the new API RP2A (22nd edition) parametric static strength prediction equations for planar circular hollow section tubular joints is described. Prediction equations are presented for brace axial, brace in-plane bending, and brace out-of-plane bending loads. The prediction equations are based on screened test databases, augmented, and extended by an extensive new series of validated nonlinear finite element simulations for nonoverlapping K joints, double tee (DT/X) joints, and T joints. The increased reliability (reduced scatter) provided by the new static strength formulation was used to justify a reduction of the load factor of safety to 1.6 from the previous value of 1.7.

Copyright © 2007 by American Society of Mechanical Engineers
Your Session has timed out. Please sign back in to continue.

References

Figures

Grahic Jump Location
Figure 1

Old (21st ed.) and new (22nd ed.) brace load interaction equations versus test and FE data

Grahic Jump Location
Figure 2

K joint geometry

Grahic Jump Location
Figure 3

Test versus FE for a DT joint loaded in brace compression (13): chord preloads P∕Py=−0.3, Mipb∕MP=−0.25. Joint geometry (β=0.67, γ=25, τ=0.8).

Grahic Jump Location
Figure 4

Test versus FE for a 45deg K joint under balanced brace axial loads (25). No additional chord loads. Joint geometry (β=0.72, γ=24, ζ=0.1, τ=0.9, α=6.6).

Grahic Jump Location
Figure 5

Effect of brace-to-chord thickness ratio on BIPB response of 45deg K joints. No additional chord loads.

Grahic Jump Location
Figure 6

Effect of brace bending moment direction on response of 45deg K joint: β=0.6, γ=10, ζ=0.15

Grahic Jump Location
Figure 7

Effect of brace angle θ on BIPB response of K joints. No chord preloads.

Grahic Jump Location
Figure 8

Comparison of strength factors Qu for brace axial loads: new API (22nd ed.) versus old API (21st ed.)

Grahic Jump Location
Figure 9

Comparison of strength factors Qu for brace bending loads: new API (22nd ed.) versus old API (21st ed.) (Note: API (21st ed.) Qu multiplied by 0.8 factor for comparisons).

Grahic Jump Location
Figure 10

Transition in chord load factor for axially loaded DT joints (β<0.9, and β=1.0) versus UTA tests (13,24)

Grahic Jump Location
Figure 11

Comparison of chord load factors Qf: new API (22nd ed.) versus old API (21st ed.)

Grahic Jump Location
Figure 12

Comparison of test and FE data versus new (22nd ed.) and old (21st ed.) API for axially loaded DTs

Grahic Jump Location
Figure 13

Comparison of test and FE data versus new (22nd ed.) and old (21st ed.) API for axially loaded Ks

Grahic Jump Location
Figure 14

Comparison of test and FE data versus new (22nd ed.) and old (21st ed.) API for axially loaded Ts

Grahic Jump Location
Figure 15

Comparison of test and FE data versus new (22nd ed.) and old (21st ed.) API for brace in-plane bending

Grahic Jump Location
Figure 16

Comparison of test and FE data versus new (22nd ed.) and old (21st ed.) API for brace out-of-plane bending

Tables

Errata

Discussions

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related Journal Articles
Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In