Experimental Studies on Galling Onset in OCTG Connections: A Review

[+] Author and Article Information
S. Ekwaro-Osire2

Department of Mechanical Engineering, Texas Tech University, Lubbock, TX 79409stephen.ekwaro-osire@ttu.edu

F. Karpat

Department of Mechanical Engineering, Uludağ University, 16059 Bursa Turkey

2

Corresponding author.

J. Energy Resour. Technol 130(1), 014502 (Feb 04, 2008) (4 pages) doi:10.1115/1.2835616 History: Received November 20, 2006; Revised November 28, 2007; Published February 04, 2008

With today’s high prices for natural gas and oil, the demand for oil and country tubular goods (OCTGs) with superior performance properties is very high. Failures in OCTG can be attributed to numerous sources, for example, makeup torque, corrosion, and galling. Thread galling is the most common mode of failure. This failure often leads to leakage, corrosion of the material, and loss of mechanical integrity. The failure of OCTG eventually amounts to excessive operational costs for the gas and oil industry. Numerous approaches have been taken to improve the galling resistance of OCTG connections. The advocacy of these approaches is often achieved through experimental studies using galling testers. There is a need to design and use effective galling testers to understand and improve the performance of OCTG connections. Thus, the objective of this paper is to present a concise review of literature related to the galling testers that may have applications to OCTG.

FIGURES IN THIS ARTICLE
<>
Copyright © 2008 by American Society of Mechanical Engineers
Your Session has timed out. Please sign back in to continue.

References

Figures

Grahic Jump Location
Figure 1

Slider-on-block tester configuration

Grahic Jump Location
Figure 2

Button-on-block tester configuration

Grahic Jump Location
Figure 3

Pin-on-disk tester configuration

Grahic Jump Location
Figure 4

Button-on-cylinder tester configuration

Grahic Jump Location
Figure 5

Crossed-cylinder tester configuration (translating specimens)

Grahic Jump Location
Figure 6

Crossed-cylinder tester configuration (translating specimen and rotating specimen)

Grahic Jump Location
Figure 7

Parallel-cylinder tester configuration (rotating cylinders)

Grahic Jump Location
Figure 8

Parallel-cylinder tester configuration (fixed cylinders)

Grahic Jump Location
Figure 9

Concentric-cylinder tester configuration

Tables

Errata

Discussions

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related Journal Articles
Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In