The time-dependent pressure curves of a pulsatile flow across rigid and pulsating stenoses were investigated experimentally in a laboratory simulator of the outflow tract of the heart right ventricle. The experiments were performed within the range of physiological conditions of frequency and flow rate. The experimental setup consisted of a closed flow system which was operated by a pulsatile pump, and a test chamber which enabled checking different modes of stenosis. Rigid constrictions were simulated by means of axisymmetric blunt-ended annular plugs with moderate-to-severe area reductions. The pulsating stenosis consisted of a short starling resistor device operated by a pulsating external pressure which was synchronized by the pulsatile flow. It was found that the shape of the time-dependent pressure curve upstream of the stenosis was different in the case of rigid stenosis than in the pulsating one. Potential clinical applications of the work may relate to diagnosis of the type of stenosis in the congenital heart disease known as Tetralogy of Fallot.
Skip Nav Destination
Article navigation
November 1984
Research Papers
An Experimental Study of Pressure Losses in Pulsatile Flows Through Rigid and Pulsating Stenosis
R. Rabinovitz,
R. Rabinovitz
Technion—Israel Institute of Technology, Haifa, Israel
Search for other works by this author on:
D. Degani,
D. Degani
Technion—Israel Institute of Technology, Haifa, Israel
Search for other works by this author on:
C. Gutfinger,
C. Gutfinger
Technion—Israel Institute of Technology, Haifa, Israel
Search for other works by this author on:
S. Milo
S. Milo
Department of Cardiac Surgery, Sheba Medical Center, Tel-Hashomer, Israel
Search for other works by this author on:
R. Rabinovitz
Technion—Israel Institute of Technology, Haifa, Israel
D. Degani
Technion—Israel Institute of Technology, Haifa, Israel
C. Gutfinger
Technion—Israel Institute of Technology, Haifa, Israel
S. Milo
Department of Cardiac Surgery, Sheba Medical Center, Tel-Hashomer, Israel
J Biomech Eng. Nov 1984, 106(4): 309-314 (6 pages)
Published Online: November 1, 1984
Article history
Received:
December 22, 1983
Revised:
February 22, 1984
Online:
June 15, 2009
Citation
Rabinovitz, R., Degani, D., Gutfinger, C., and Milo, S. (November 1, 1984). "An Experimental Study of Pressure Losses in Pulsatile Flows Through Rigid and Pulsating Stenosis." ASME. J Biomech Eng. November 1984; 106(4): 309–314. https://doi.org/10.1115/1.3138499
Download citation file:
Get Email Alerts
Cited By
Simulating the Growth of TATA-Box Binding Protein-Associated Factor 15 Inclusions in Neuron Soma
J Biomech Eng (December 2024)
Related Articles
A Pulsatile-Flow Model for Intracardiac Surgical Device Development
J. Med. Devices (June,2011)
Pulsatile Flow Computational Simulations of Mitral Regurgitation
J Biomech Eng (April,1998)
Computational Model for the Transition From Peristaltic to Pulsatile Flow in the Embryonic Heart Tube
J Biomech Eng (June,2007)
Related Proceedings Papers
Related Chapters
Openings
Guidebook for the Design of ASME Section VIII Pressure Vessels
Role of Artificial Intelligence in Hepatitis B Diagnosis
International Conference on Mechanical and Electrical Technology, 3rd, (ICMET-China 2011), Volumes 1–3
Piping Design
Power Boilers: A Guide to the Section I of the ASME Boiler and Pressure Vessel Code, Second Edition