Screws placed into cancellous bone in orthopedic surgical applications, such as fixation of fractures of the femoral neck or the lumbar spine, can be subjected to high loads. Screw pullout is a possibility, especially if low density osteoporotic bone is encountered. The overall goal of this study was to determine how screw thread geometry, tapping, and cannulation affect the holding power of screws in cancellous bone and determine whether current designs achieve maximum purchase strength. Twelve types of commercially available cannulated and noncannulated cancellous bone screws were tested for pullout strength in rigid unicellular polyurethane foams of apparent densities and shear strengths within the range reported for human cancellous bone. The experimentally derived pullout strength was compared to a predicted shear failure force of the internal threads formed in the polyurethane foam. Screws embedded in porous materials pullout by shearing the internal threads in the porous material. Experimental pullout force was highly correlated to the predicted shear failure force (slope = 1.05, R2 = 0.947) demonstrating that it is controlled by the major diameter of the screw, the length of engagement of the thread, the shear strength of the material into which the screw is embedded, and a thread shape factor (TSF) which accounts for screw thread depth and pitch. The average TSF for cannulated screws was 17 percent lower than that of noncannulated cancellous screws, and the pullout force was correspondingly less. Increasing the TSF, a result of decreasing thread pitch or increasing thread depth, increases screw purchase strength in porous materials. Tapping was found to reduce pullout force by an average of 8 percent compared with nontapped holes (p = 0.0001). Tapping in porous materials decreases screw pullout strength because the removal of material by the tap enlarges hole volume by an average of 27 percent, in effect decreasing the depth and shear area of the internal threads in the porous material.
Skip Nav Destination
Article navigation
August 1996
Technical Papers
Factors Affecting the Pullout Strength of Cancellous Bone Screws
J. R. Chapman,
J. R. Chapman
Harborview Biomechanics Laboratory of the Department of Orthopaedics, University of Washington, Seattle, WA 98195
Search for other works by this author on:
R. M. Harrington,
R. M. Harrington
Harborview Biomechanics Laboratory of the Department of Orthopaedics, University of Washington, Seattle, WA 98195
Search for other works by this author on:
K. M. Lee,
K. M. Lee
Harborview Biomechanics Laboratory of the Department of Orthopaedics, University of Washington, Seattle, WA 98195
Search for other works by this author on:
P. A. Anderson,
P. A. Anderson
Harborview Biomechanics Laboratory of the Department of Orthopaedics, University of Washington, Seattle, WA 98195
Search for other works by this author on:
A. F. Tencer,
A. F. Tencer
Harborview Biomechanics Laboratory of the Department of Orthopaedics, University of Washington, Seattle, WA 98195
Search for other works by this author on:
D. Kowalski
D. Kowalski
Harborview Biomechanics Laboratory of the Department of Orthopaedics, University of Washington, Seattle, WA 98195
Search for other works by this author on:
J. R. Chapman
Harborview Biomechanics Laboratory of the Department of Orthopaedics, University of Washington, Seattle, WA 98195
R. M. Harrington
Harborview Biomechanics Laboratory of the Department of Orthopaedics, University of Washington, Seattle, WA 98195
K. M. Lee
Harborview Biomechanics Laboratory of the Department of Orthopaedics, University of Washington, Seattle, WA 98195
P. A. Anderson
Harborview Biomechanics Laboratory of the Department of Orthopaedics, University of Washington, Seattle, WA 98195
A. F. Tencer
Harborview Biomechanics Laboratory of the Department of Orthopaedics, University of Washington, Seattle, WA 98195
D. Kowalski
Harborview Biomechanics Laboratory of the Department of Orthopaedics, University of Washington, Seattle, WA 98195
J Biomech Eng. Aug 1996, 118(3): 391-398 (8 pages)
Published Online: August 1, 1996
Article history
Received:
September 2, 1994
Revised:
August 10, 1995
Online:
October 30, 2007
Citation
Chapman, J. R., Harrington, R. M., Lee, K. M., Anderson, P. A., Tencer, A. F., and Kowalski, D. (August 1, 1996). "Factors Affecting the Pullout Strength of Cancellous Bone Screws." ASME. J Biomech Eng. August 1996; 118(3): 391–398. https://doi.org/10.1115/1.2796022
Download citation file:
Get Email Alerts
We Will, We Will Shock You: Adaptive Versus Conventional Functional Electrical Stimulation in Individuals Post-Stroke
J Biomech Eng (December 2024)
Evaluation of an Inverse Method for Quantifying Spatially Variable Mechanics
J Biomech Eng (December 2024)
Effect of Structure and Wearing Modes on the Protective Performance of Industrial Safety Helmet
J Biomech Eng (December 2024)
Sex-Based Differences and Asymmetry in Hip Kinematics During Unilateral Extension From Deep Hip Flexion
J Biomech Eng (December 2024)
Related Articles
Compressive and Shear Properties of Commercially Available Polyurethane Foams
J Biomech Eng (October,2003)
High Speed Fracture Fixation: Assessing Resulting Fixation Stability and Fastener Withdrawal Strength
J Biomech Eng (September,2013)
Numerical Simulation of Cropping
J. Appl. Mech (July,2014)
Analysis of the Mechanics of Machining with Tapered End Milling Cutters
J. Eng. Ind (August,1994)
Related Proceedings Papers
Related Chapters
Introduction and Definitions
Handbook on Stiffness & Damping in Mechanical Design
Crack(s) in a Rod or a Plate by Energy Rate Analysis
The Stress Analysis of Cracks Handbook, Third Edition
Understanding the Problem
Design and Application of the Worm Gear