Abstract

A remarkable amount of energy in data centers is consumed in eliminating the heat generated by the information technology (IT) equipment to maintain and ensure safe operating conditions and optimum performance. The installation of airside economizers (ASEs), while very energy efficient, bears the risk of particulate contamination in data centers, hence, deteriorating the reliability of IT equipment. When relative humidity (RH) in data centers exceeds the deliquescent relative humidity (DRH) of salts or accumulated particulate matter, it absorbs moisture, becomes wet, and subsequently leads to electrical short-circuiting because of degraded surface insulation resistance (SIR) between the closely spaced features on printed circuit boards (PCBs). Another concern with this type of failure is the absence of evidence that hinders the process of evaluation and rectification. Therefore, it is imperative to develop a practical test method to determine the DRH value of the accumulated particulate matter found on PCBs. This research is a first attempt to develop an experimental technique to measure the DRH of dust particles by logging the leakage current versus RH% for the particulate matter dispensed on an interdigitated comb coupon. To validate this methodology, the DRH of pure salts like MgCl2, NH4NO3, and NaCl is determined, and their results are then compared with their published values. This methodology was therefore implemented to help lay a modus operandi of establishing the limiting value or an effective relative humidity envelope to be maintained at a real-world data center facility situated in Dallas industrial area for its continuous and reliable operation.

References

1.
ASHRAE Technical Committee 9.9
,
2010
, “ASHRAE DOE Course: Save Energy Now Presentation Series,” American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Dallas, TX.
2.
Energy Star
,
2018
, “
Air-Side Economizer
,” U.S. Environmental Protection Agency (EPA) and United States Department of Energy (DOE), Washington, DC, accessed June 17, 2020, www.energystar.gov/index.cfm?c=power_mgt.datacenter_efficiency_economizer_airside
3.
Singh
,
P.
,
Klein
,
L.
,
Agonafer
,
D.
,
Shah
,
J. M.
, and
Pujara
,
K. D.
, “
Effect of Relative Humidity, Temperature and Gaseous and Particulate Contaminations on Information Technology Equipment Reliability
,”
ASME
Paper No. IPACK2015-48176.10.1115/IPACK2015-48176
4.
Thirunavakkarasu
,
G.
,
Saini
,
S.
,
Shah
,
J. M.
, and
Agonafer
,
D.
, “
Air Flow Pattern and Path Flow Simulation of Airborne Particulate Contaminants in a High-Density Data Center Utilizing Airside Economization
,”
ASME
Paper No. IPACK2018-8436.10.1115/IPACK2018-8436
5.
Shah
,
J. M.
,
2016
, “
Reliability Challenges in Airside Economization and Oil Immersion Cooling
,”
Master's thesis
,
University of Texas at Arlington
, Arlington, TX.https://rc.library.uta.edu/uta-ir/handle/10106/25923
6.
Saini
,
S.
,
2018
, “
Airflow Path and Flow Pattern Analysis of Sub-Micron Particulate Contaminants in a Data Center With Hot-Aisle Containment Utilizing Direct Air Cooling
,”
Master's thesis
,
University of Texas at Arlington
, Arlington, TX.https://rc.library.uta.edu/uta-ir/bitstream/handle/10106/28319/SAINI-THESIS-2018.pdf?sequence=1
7.
Shah
,
J. M.
,
Awe
,
O.
,
Agarwal
,
P.
,
Iziren
,
A.
,
Agonafer
,
D.
,
Singh
,
P.
,
Kannan
,
N.
, and
Kaler
,
M.
,
2016
, “
Qualitative Study of Cumulative Corrosion Damage of IT Equipment in a Data Center Utilizing Air-Side Economizer
,”
ASME
Paper No. IMECE2016-66199.10.1115/IMECE2016-66199
8.
Shah
,
J. M.
,
Awe
,
O.
,
Gebrehiwot
,
B.
,
Agonafer
,
D.
,
Singh
,
P.
,
Kannan
,
N.
, and
Kaler
,
M.
,
2017
, “
Qualitative Study of Cumulative Corrosion Damage of Information Technology Equipment in a Data Center Utilizing Air-Side Economizer Operating in Recommended and Expanded ASHRAE Envelope
,”
ASME J. Electron. Packag.
,
139
(
2
), p.
020903
.10.1115/1.4036363
9.
Cole
,
M.
,
Hedlund
,
L.
,
Hutt
,
G.
,
Kiraly
,
T.
,
Klein
,
L.
,
Nickel
,
S.
,
Singh
,
P.
, and
Tofil
,
T.
,
2010
, “Harsh Environmental Impact on Resistor Reliability,” SMTA International Conference, Orlando, FL, Oct. 24–28, Paper No.
SMTAI10HE2
.https://www.researchgate.net/publication/288027013_Harsh_environment_impact_on_resistor_reliability
10.
European Union
,
2003
, “
Directive 2002/95/EC of the European Parliament and of the Council of 27 January 2003 on the Restriction of the Use of Certain Hazardous Substances on Electrical and Electronic Equipment
,”
Off. J. Eur. Union, L037
, pp.
19
23
.https://eur-lex.europa.eu/LexUriServ/LexUriServ.do?uri=OJ:L:2003:037:0019:0023:EN:PDF#:~:text=The%20available%20evidence%20indicates%20that,equipment(6)%20are%20necessary%20to
11.
Fu
,
H.
,
Chen
,
C.
,
Singh
,
P.
,
Zhang
,
J.
,
Kurella
,
A.
,
Chen
,
X.
,
Jiang
,
X.
,
Burlingame
,
J.
, and
Lee
,
S.
,
2012
, “
Investigation of Factors That Influence Creep Corrosion on Printed Circuit Boards
,”
SMTA Pan Pacific Microelectronics Symposium
, Kauai, Hawaii, Feb. 14–16, Paper No.
PP2012_WA1.4
.http://thor.inemi.org/webdownload/Pres/SMTA_Pan_Pacific-2012/Creep_Corr_paper.pdf
12.
Fu
,
H.
,
Chen
,
C.
,
Singh
,
P.
,
Zhang
,
J.
,
Kurella
,
A.
,
Chen
,
X.
,
Jiang
,
X.
,
Burlingame
,
J.
, and
Lee
,
S.
,
2012
, “
Investigation of Factors that Influence Creep Corrosion on Printed Circuit Boards—Part 2: SMTAI
,”
SMTA International Conference Proceedings
, Orlando, FL, Oct. 14–18.https://www.smta.org/knowledge/proceedings_abstract.cfm?PROC_ID=3516
13.
Jud Ready
,
W.
,
Turbini
,
L. J.
,
Nickel
,
R.
, and
Fischer
,
J.
,
1999
, “
A Novel Test Circuit for Automatically Detecting Electrochemical Migration and Conductive
,”
J. Electron. Mater.
,
28
(
11
), pp.
1158
1163
.10.1007/s11664-999-0151-6
14.
Wan
,
J. W.
,
Gao
,
J. C.
,
Lin
,
X. Y.
, and
Zhang
,
J. G.
,
1999
, “
Water-Soluble Salts in Dust and Their Effects on Electric Contact Surfaces
,”
Proceedings of the International Conference on Electrical Contacts, Electromechanical Components and Their Applications
, Nagoya, Japan, July 19–24, p.
37
.
15.
Singh, P., Ruch
,
P.
,
Saliba
,
S.
, and
Muller
,
C.
,
2015
, “
Characterization, Prevention and Removal of Particulate Matter on Printed Circuit Boards
,”
IPC APEX
, San Diego, CA.https://smtnet.com/library/files/upload/particulate-matter-removal-pcb.pdf
16.
Shah
,
J. M.
,
Misrak
,
A.
,
Agonafer
,
D.
, and
Kaler
,
M.
,
2019
, “
Identification and Characterization of Particulate Contaminants Found at a Data Center Using Airside Economization
,”
ASME J. Electron. Packag.
,
141
(
3
), p.
031003
.10.1115/1.4043481
17.
Yang
,
L.
,
Pabalan
,
R. T.
, and
Juckett
,
M. R.
,
2006
, “
Deliquescence Relative Humidity Measurements Using an Electrical Conductivity Method
,”
J. Solution Chem.
,
35
(
4
), pp.
583
604
.10.1007/s10953-005-9015-8
18.
Yang
,
L.
,
Pabalan
,
R. T.
, and
Browning, L.
,
2002
, “
Experimental Determination of the Deliquescence Relative Humidity and Conductivity of Multicomponent Salt Mixtures
,”
MRS Proceedings
, San Francisco, CA, Apr. 2–5, Vol. 713, p. JJ11.4.10.1557/PROC-713-JJ11.4
19.
Anand
,
R.
,
2018
, “
Development and Validation of the Deliquescent Relative Humidity Test Method for the Accumulated Particulate Matter Found in a Data Center Utilizing an Airside Economizer
,”
Master's thesis
,
University of Texas at Arlington
, Arlington, TX.https://rc.library.uta.edu/uta-ir/handle/10106/28297
20.
Shah
,
J. M.
,
2018
, “
Characterizing Contamination to Expand ASHRAE Envelope in Airside Economization and Thermal and Reliability in Immersion Cooling of Data Centers
,”
PhD dissertation
,
University of Texas at Arlington
, Arlington, TX.https://rc.library.uta.edu/uta-ir/handle/10106/28654
21.
Awe
,
O.
,
Shah
,
J. M.
,
Agonafer
,
D.
,
Singh
,
P.
,
Kannan
,
N.
, and
Kaler
,
M.
,
2020
, “
Experimental Description of Information Technology Equipment Reliability Exposed to a Data Center Using Airside Economizer Operating in Recommended and Allowable ASHRAE Envelopes in an ANSI/ISA Classified G2 Environment
,”
ASME. J. Electron. Packag.
, 142(2), p.
024501
.10.1115/1.4046556
22.
Shah
,
J. M.
,
Anand
,
R.
,
Saini
,
S.
,
Cyriac
,
R.
,
Agonafer
,
D.
,
Singh
,
P.
, and
Kaler
,
M.
,
2019
, “
Development of a Technique to Measure Deliquescent Relative Humidity of Particulate Contaminants and Determination of the Operating Relative Humidity of a Data Center
,”
ASME
Paper No. IPACK2019-6601.10.1115/IPACK2019-6601
You do not currently have access to this content.