In a previous paper [1], the analysis of pump suction pressure decay utilizing the varying condensate temperature approach was first introduced. Although the paper provided power plant engineers with an accurate analytical method for determining the magnitude of feedwater pump suction pressure decay, no protective method to prevent or alleviate the pressure decay under instant turbine load rejection was mentioned. As unit size has rapidly increased in recent years, the power plant deaerator requires not only a larger storage capacity but also must be elevated higher to protect the boiler feed pumps against suction pressure decay under load rejection. Since this trend is expected to continue, the cost of supporting the power plant deaerator may soon become prohibitive. Several protective methods have been previously introduced. However, the evaluation of the methods was invariably based on the constant-condensate-temperature approach, which is not suitable for central station regenerative cycle units. This paper reevaluates those methods in general and recommends the on-off type deaerator bypass system as the most effective and economical method. The use of this protective method will not only reduce deaerator storage capacity to the absolute minimum as required solely for surge, but will also largely preclude the provision of additional static head for instant load reduction. As a result, enormous savings can be expected both from the deaerator itself and its supporting structures. The magnitude of savings in supporting structures alone may amount to more than a half million dollars for a 750 MW fossile unit. Based on the varying condensate temperature approach, mathematical equations expressing the deaerator pressure decay as well as design parameters required for designing the protective system have been derived. The paper also presents a detailed description of the recommended protective system and discusses some advantages of this system over the others. Finally, a few engineering examples are included to illustrate the application in system design.
Skip Nav Destination
Article navigation
July 1974
This article was originally published in
Journal of Engineering for Power
Research Papers
Protection of Boiler Feed Pump Against Transient Suction Pressure Decay
G. S. Liao
G. S. Liao
Los Angeles Power Division, Bechtel Power Corp., Los Angeles, Calif.
Search for other works by this author on:
G. S. Liao
Los Angeles Power Division, Bechtel Power Corp., Los Angeles, Calif.
J. Eng. Power. Jul 1974, 96(3): 247-254 (8 pages)
Published Online: July 1, 1974
Article history
Received:
July 10, 1973
Online:
July 14, 2010
Article
Article discussed|
View article
Connected Content
Citation
Liao, G. S. (July 1, 1974). "Protection of Boiler Feed Pump Against Transient Suction Pressure Decay." ASME. J. Eng. Power. July 1974; 96(3): 247–254. https://doi.org/10.1115/1.3445801
Download citation file:
Get Email Alerts
Cited By
Multi-Disciplinary Optimization of Gyroid Topologies for a Cold Plate Heat Exchanger Design
J. Eng. Gas Turbines Power
Comparison of Rim Sealing Effectiveness in Different Geometrical Configurations
J. Eng. Gas Turbines Power
Related Articles
Analysis of Feedwater Pump Suction Pressure Decay Under Instant Turbine Load Rejection
J. Eng. Power (April,1972)
Analysis of Drain Pumping System for Nuclear Power Plants Under Transient Turbine Loads
J. Eng. Power (October,1975)
Testing Large Steam Turbines With Weighing Tanks
Trans. ASME (January,1955)
Optimization of Advanced Steam Condition Power Plants
J. Eng. Gas Turbines Power (October,1992)
Related Proceedings Papers
Related Chapters
Lay-Up and Start-Up Practices
Consensus on Operating Practices for Control of Water and Steam Chemistry in Combined Cycle and Cogeneration
Combined Cycle Power Plant
Energy and Power Generation Handbook: Established and Emerging Technologies
Importance of Effective Monitoring
Consensus on Operating Practices for the Sampling and Monitoring of Feedwater and Boiler Water Chemistry in Modern Industrial Boilers (CRTD-81)