Condensation of a vapor flow inside a horizontal rectangular duct, using the bottom plate as the only condensing surface, was experimentally investigated. The experimental measurements included condensate film thickness and heat transfer coefficients with R-113 and FC-72. The condensate film thickness, measured with an ultrasonic transducer, was used to obtain the local heat transfer coefficient. The heat transfer coefficient increased with increasing inlet vapor velocity. The rate of increase was enhanced noticeably after the appearance of interfacial waves. Within the limited range of the experimental variables, a correlation between St and RegL was developed by a linear regression analysis. However, because of the effect of the interfacial waves, instead of a single correlation for the entire range of RegL, two separate equations (one for the wave-free regime and another for the regime with waves) were found. Analytical predictions of heat transfer rates in the annular condensation regime require the proper modeling of the interfacial shear stress. A properly validated interfacial shear stress model with condensation is not yet available. The measurement of condensate film thickness at several axial locations opens the door for determining the local interfacial stress and, hence, a model for the interfacial shear stress.
Skip Nav Destination
Article navigation
Research Papers
Condensation of a Vapor Flowing Inside a Horizontal Rectangular Duct
Q. Lu,
Q. Lu
Department of Mechanical Engineering and Engineering Mechanics, Michigan Technological University, Houghton, MI 49931
Search for other works by this author on:
N. V. Suryanarayana
N. V. Suryanarayana
Department of Mechanical Engineering and Engineering Mechanics, Michigan Technological University, Houghton, MI 49931
Search for other works by this author on:
Q. Lu
Department of Mechanical Engineering and Engineering Mechanics, Michigan Technological University, Houghton, MI 49931
N. V. Suryanarayana
Department of Mechanical Engineering and Engineering Mechanics, Michigan Technological University, Houghton, MI 49931
J. Heat Transfer. May 1995, 117(2): 418-424 (7 pages)
Published Online: May 1, 1995
Article history
Received:
April 1, 1993
Revised:
June 1, 1994
Online:
December 5, 2007
Citation
Lu, Q., and Suryanarayana, N. V. (May 1, 1995). "Condensation of a Vapor Flowing Inside a Horizontal Rectangular Duct." ASME. J. Heat Transfer. May 1995; 117(2): 418–424. https://doi.org/10.1115/1.2822538
Download citation file:
Get Email Alerts
Cited By
Related Articles
Forced Convection Film Condensation on a Horizontal Tube—Influence of Vapor Boundary-Layer Separation
J. Heat Transfer (May,1995)
Experiments for the Determination of Convective Diffusion Heat/Mass Transfer to Burner Rig Test Targets Comparable in Size to Jet Stream Diameter
J. Heat Transfer (May,1988)
Condensation of Ethylene Glycol on Integral-Fin Tubes: Effect of Fin Geometry and Vapor Velocity
J. Heat Transfer (November,2005)
Numerical Simulation of Evaporating Two-Phase Flow in a High-Aspect-Ratio Microchannel with Bends
J. Heat Transfer (August,2017)
Related Proceedings Papers
Related Chapters
Evaluation of Moisture Accumulation in Composite Roof Decks in High Humidity Environments such as Natatoriums in Cold Climates Using Hygrothermal Modeling
Roofing Research and Standards Development: 10th Volume
Condensation in Cool Roofs—Code Challenges, Field Observations, and Hygrothermal Modeling
Roofing Research and Standards Development: 10th Volume
Climate Control Isn't Natural
Hot Air Rises and Heat Sinks: Everything You Know about Cooling Electronics Is Wrong