Intraoperative range of motion (ROM) assessment can be challenging during total knee arthroplasty (TKA) surgery. As computer assisted surgery is costly and not readily available to many surgeons, we have developed a simple, cost-effective intraoperative device to precisely measure knee flexion and extension. A simple knee goniometer system was constructed consisting of a digital level mounted to a base that rigidly attaches two standard needles. The needles are pushed through the overlying soft tissue of the distal femur. The device is then applied to the proximal tibia, where an angle measurement of the knee is registered. A validation study for this device was conducted on two pairs of intact cadaveric lower limbs at 0 deg, 10 deg, 15 deg, 20 deg, 25 deg, and 30 deg. Two orthopedic surgeons experienced with the system performed three measurements at each angle. Systematic error, defined as the goniometer reading at 0 deg flexion anatomically as determined by the navigation system, ranged from −9.1 deg to 3.0 deg, consistent for each operator on every case. Measurement error, defined as the variability in repeated, fixed angle measurements made with the goniometer, was 1.5 ± 1.0 deg across all surgeons, cases, and prescribed flexion angles. For both surgeons and all imposed flexion angles, measurement errors were below the 4 deg clinical threshold. The simple knee goniometer system generated accurate, repeatable measures of changes in flexion angle intraoperatively with measurement error comparable to errors obtained using the commercial navigation system (1 deg–2 deg). However, the knee goniometer is less complex, less time intensive, and less costly than currently available computer assistive devices. Taken together, our results are very promising for the continued development of this device.
Skip Nav Destination
The Taylor Collaboration,
St. Mary's Medical Center,
University of California,
The Taylor Collaboration,
St. Mary's Medical Center,
Biomechanical Testing Facility,
University of California,
Article navigation
March 2013
Research-Article
A Simple Goniometer for Use Intraoperatively in Total Knee Arthroplasty
J. Peter,
The Taylor Collaboration,
St. Mary's Medical Center,
J. Peter
San Francisco Orthopaedic Residency Program
,The Taylor Collaboration,
St. Mary's Medical Center,
San Francisco, CA
Search for other works by this author on:
J. M. Currey,
University of California,
J. M. Currey
Biomechanical Testing Facility
,University of California,
San Francisco, CA
Search for other works by this author on:
J. M. Buckley,
The Taylor Collaboration,
St. Mary's Medical Center,
Biomechanical Testing Facility,
University of California,
J. M. Buckley
San Francisco Orthopaedic Residency Program
,The Taylor Collaboration,
St. Mary's Medical Center,
San Francisco, CA
;Biomechanical Testing Facility,
University of California,
San Francisco, CA
Search for other works by this author on:
K. D. Liddle
K. D. Liddle
Biomechanical Testing Facility, University of California
, San Francisco, CA
Search for other works by this author on:
J. Peter
San Francisco Orthopaedic Residency Program
,The Taylor Collaboration,
St. Mary's Medical Center,
San Francisco, CA
J. M. Currey
Biomechanical Testing Facility
,University of California,
San Francisco, CA
J. M. Buckley
San Francisco Orthopaedic Residency Program
,The Taylor Collaboration,
St. Mary's Medical Center,
San Francisco, CA
;Biomechanical Testing Facility,
University of California,
San Francisco, CA
K. D. Liddle
Biomechanical Testing Facility, University of California
, San Francisco, CA
Manuscript received April 17, 2012; final manuscript received October 12, 2012; published online February 13, 2013. Assoc. Editor: Hamid M. Lankarani.
J. Med. Devices. Mar 2013, 7(1): 011010 (3 pages)
Published Online: February 13, 2013
Article history
Received:
April 17, 2012
Revision Received:
October 12, 2012
Citation
McGann, W., Peter, J., Currey, J. M., Buckley, J. M., and Liddle, K. D. (February 13, 2013). "A Simple Goniometer for Use Intraoperatively in Total Knee Arthroplasty." ASME. J. Med. Devices. March 2013; 7(1): 011010. https://doi.org/10.1115/1.4023289
Download citation file:
Get Email Alerts
Cited By
Related Articles
Joint Gap Kinematics in Posterior-Stabilized Total Knee Arthroplasty Measured by a New Tensor With the Navigation System
J Biomech Eng (December,2006)
Design and Cadaveric Validation of a Novel Device to Quantify Knee Stability During Total Knee Arthroplasty
J Biomech Eng (November,2012)
Anatomical Study of the Radius and Center of Curvature of the Distal Femoral Condyle
J Biomech Eng (September,2010)
Evaluation of Clinical and Technical Parameters to Customize Total Knee Arthroplasty Implants
J. Comput. Inf. Sci. Eng (December,2022)
Related Proceedings Papers
Related Chapters
Flexibility of the Human Knee as a Result of Varus/Valgus and Axial Moments in Vivo: Apparatus Design and Performance Evaluation
Skiing Trauma and Safety: Eighth International Symposium
Strains Within the Anterior Cruciate and Medial Collateral Ligaments of the Knee at Loads Causing Failure
Skiing Trauma and Safety: Ninth International Symposium
Potential Risk Factors for Knee Injuries in Alpine Skiers
Skiing Trauma and Safety: 17th Volume