Skip Nav Destination
Close Modal
Update search
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
NARROW
Format
Article Type
Subject Area
Topics
Date
Availability
1-5 of 5
Keywords: calibration
Close
Follow your search
Access your saved searches in your account
Would you like to receive an alert when new items match your search?
Sort by
Journal Articles
Journal:
Journal of Medical Devices
Publisher: ASME
Article Type: Research Papers
J. Med. Devices. December 2009, 3(4): 041002.
Published Online: November 19, 2009
... directions to be isolated. An electromagnetic tracking system is used for position tracking. Two prototypes of the sensorized instrument were constructed. Position calibration shows a maximum root mean square (RMS) error of 1.3 mm. The results of the force calibration show a maximum RMS error of 0.35 N...
Journal Articles
Journal:
Journal of Medical Devices
Publisher: ASME
Article Type: Design Of Medical Devices Conference Abstracts
J. Med. Devices. June 2008, 2(2): 027542.
Published Online: June 25, 2008
...Alexander H. Slocum, Jr.; Stephen E. Jones, MD; Rajiv Gupta, MD A calibration phantom that can be used to measure the temporal resolution of a CT scanner was designed utilizing a deterministic design process. The system was first defined in terms of a set of functional requirements based...
Journal Articles
Journal:
Journal of Medical Devices
Publisher: ASME
Article Type: Research Papers
J. Med. Devices. March 2008, 2(1): 011006.
Published Online: March 11, 2008
... ∕ μ m , or apparent elastic modulus of 40 MPa – 1.80 GPa ). Finite element analysis (FEA) was used to calculate the rigidity of each RB and was validated with physical testing in a universal testing machine. Results from FEA were then used to calibrate the system and relate force, piezoelectric...
Journal Articles
Journal:
Journal of Medical Devices
Publisher: ASME
Article Type: Design Innovation Paper
J. Med. Devices. September 2007, 1(3): 225–232.
Published Online: August 13, 2007
...Alexander H. Slocum, Jr.; Stephen E. Jones; Rajiv Gupta This paper describes the design and development of a calibration phantom to be used to aid in the calculation of the temporal resolution of tomographic imaging devices. Current practice for characterizing the dynamic response of a tomographic...
Journal Articles
Journal:
Journal of Medical Devices
Publisher: ASME
Article Type: Research Papers
J. Med. Devices. September 2007, 1(3): 197–205.
Published Online: August 6, 2007
...-tissue compliance meter. Our motivation was to improve the compliance realism of our virtual haptic back model, but there are many potential applications for this method. We present calibration of the haptic interface, pseudostatic compliance measurement techniques, measurement of contracted muscle...