Currently, available sleep monitoring systems use electrical recording where the electrodes make contact with the patient’s skin using a conducting gel. The electrode wires are connected to a processing recording system. The subject has to be in close proximity of these machines due to the direct electrical connections with the body and the machine. The conductive gel along with many wires connected to the biopotential electrodes makes them uncomfortable for the subject, with the result that recording and monitoring of the patient’s sleep patterns can become very difficult. The patient has to be in a sleep lab and/or a hospital at all times and at least one technician needs to watch the patient’s sleep behavior via video. The patient may not experience normal sleep patterns under such environments and as such, the diagnostic results are not really very conclusive. The commonly monitored biopotential electrodes are electrocardiogram, electroencephalogram, electromyogram, and electrooculogram. The electrodes used for monitoring these signals are Ag/AgCl and gold, which require skin preparation by means of scrubbing to remove the dead cells and application of electrolytic gel to reduce the skin contact resistance. The gel takes a role of reducing skin contact impedance in the conventional Ag/AgCl electrode and its usage is directly related to the sensitivity. However, the wet conventional Ag/AgCl electrode has some drawbacks such as difficulty in long time monitoring because the gel dries out after few hours and skin irritations. Usually, physiological parameters are monitored over an extended period of time during the patient’s normal daily life to diagnose a disease. In this case, the wet conventional Ag/AgCl cannot be used because of the dry-out of gel. The dry-out of gel increases the impedance between skin and electrode and it is reflected in the poor signal sensitivity. Also noises, such as motion artifact and baseline wander, are added to the biopotential signals as the electrode floats over the electrolytic gel during monitoring. To overcome these drawbacks, dry nanoelectrodes are proposed in this paper where the electrodes are held against the skin surface to establish contact with the skin without the need for electrolytic fluids or gels. The results are presented along with a wireless communication such that the proposed system is ideal for point-of-care diagnosis of the patient at home.

1.
Kost
,
G. J.
, 1995, “
Guidelines for Point-of-Care Testing: Improving Patient Outcomes
,”
Am. J. Clin. Pathol.
0002-9173,
104
, pp.
111
127
.
2.
Varshney
,
U.
, and
Sneha
,
S.
, 2006, “
Patient Monitoring Using Wireless Nwtworks: Reliability and Power Management
,”
IEEE Communications
, pp.
49
55
.
3.
Figueredo
,
M. V. M.
, and
Dias
,
J. S.
, 2004, “
Mobile Telemedicine System for Home Care and Patient Monitoring
,”
Proceedings of the 26th Annual IEEE EMBS International Conference
, pp.
3387
3390
.
4.
Teplan
,
M.
, 2002, “
Fundamentals of EEG Measurement
,”
Measurement Science Review
, Vol.
2
,
Institute of Measurement Science, Slovak Academy of Sciences
,
Bratislava, Slovakia
.
5.
Bickford
,
R. D.
, 1897,
Encyclopedia of Neuroscience
,
G.
Adelman
, ed.,
Birkhauser
,
Cambridge
.
6.
Malmivuo
,
J.
, and
Plonsey
,
R.
, “
Bioelectromagnetism
,” Chap. 28, retrieved July 7, 2009, http://www.bem.fi/book/index.htmhttp://www.bem.fi/book/index.htm
7.
Malmivuo
,
J.
, and
Plonsey
,
R.
, “
Bioelectromagnetism
,” Chap. 13, retrieved July 7, 2009, http://www.bem.fi/book/index.htmhttp://www.bem.fi/book/index.htm
8.
Searle
,
A.
, and
Kirkup
,
L.
, 2000, “
A Direct Comparison of Wet, Dry, and Insulating Bioelectric Recording Electrodes
,”
Physiol. Meas
0967-3334,
22
, pp.
71
83
.
9.
Martin
,
T.
,
Jovanov
,
E.
, and
Raskovic
,
D.
, 2000, “
Issues in Wearable Computing for Medical Monitoring Applications: A Case Study of a Wearable ECG Monitoring Device
,”
Proceedings of the Fourth IEE International Symposium on Wearable Computers
, pp.
43
49
.
10.
Griss
,
P.
,
Tolvanen-Laakso
,
H. K.
,
Merilainen
,
P.
, and
Stemme
,
G.
, 2002, “
Characterisation of Micromachined Spike Electrodes for Biopotential Measurements
,”
IEEE Trans. Biomed. Eng.
0018-9294,
49
, pp.
597
604
.
11.
Ruffini
,
G.
,
Dunnea
,
S.
,
Farres
,
E.
,
Marco-Pallares
,
J.
,
Raya
,
C.
,
Mendozab
,
E.
,
Silva
,
R.
, and
Grau
,
C.
, 2006, “
A Dry Electrophysiology Electrode Using CNT Arrays
,”
Sens. Actuators, A
0924-4247,
132
, pp.
34
41
.
You do not currently have access to this content.