Currently, available sleep monitoring systems use electrical recording where the electrodes make contact with the patient’s skin using a conducting gel. The electrode wires are connected to a processing recording system. The subject has to be in close proximity of these machines due to the direct electrical connections with the body and the machine. The conductive gel along with many wires connected to the biopotential electrodes makes them uncomfortable for the subject, with the result that recording and monitoring of the patient’s sleep patterns can become very difficult. The patient has to be in a sleep lab and/or a hospital at all times and at least one technician needs to watch the patient’s sleep behavior via video. The patient may not experience normal sleep patterns under such environments and as such, the diagnostic results are not really very conclusive. The commonly monitored biopotential electrodes are electrocardiogram, electroencephalogram, electromyogram, and electrooculogram. The electrodes used for monitoring these signals are Ag/AgCl and gold, which require skin preparation by means of scrubbing to remove the dead cells and application of electrolytic gel to reduce the skin contact resistance. The gel takes a role of reducing skin contact impedance in the conventional Ag/AgCl electrode and its usage is directly related to the sensitivity. However, the wet conventional Ag/AgCl electrode has some drawbacks such as difficulty in long time monitoring because the gel dries out after few hours and skin irritations. Usually, physiological parameters are monitored over an extended period of time during the patient’s normal daily life to diagnose a disease. In this case, the wet conventional Ag/AgCl cannot be used because of the dry-out of gel. The dry-out of gel increases the impedance between skin and electrode and it is reflected in the poor signal sensitivity. Also noises, such as motion artifact and baseline wander, are added to the biopotential signals as the electrode floats over the electrolytic gel during monitoring. To overcome these drawbacks, dry nanoelectrodes are proposed in this paper where the electrodes are held against the skin surface to establish contact with the skin without the need for electrolytic fluids or gels. The results are presented along with a wireless communication such that the proposed system is ideal for point-of-care diagnosis of the patient at home.
Skip Nav Destination
Article navigation
August 2010
Research Papers
Wireless Point-of-Care Diagnosis for Sleep Disorder With Dry Nanowire Electrodes
Vijay K. Varadan,
Vijay K. Varadan
21st Century Endowed Chair in Nano- and Bio-Technologies and Medicine
University of Arkansas
, Fayetteville, AR 72701
Search for other works by this author on:
Sechang Oh,
Sechang Oh
Department of Electrical Engineering,
University of Arkansas
, Fayetteville, AR 72701
Search for other works by this author on:
Hyeokjun Kwon,
Hyeokjun Kwon
Department of Electrical Engineering,
University of Arkansas
, Fayetteville, AR 72701
Search for other works by this author on:
Phillip Hankins
Phillip Hankins
Department of Electrical Engineering,
University of Arkansas
, Fayetteville, AR 72701
Search for other works by this author on:
Vijay K. Varadan
21st Century Endowed Chair in Nano- and Bio-Technologies and Medicine
University of Arkansas
, Fayetteville, AR 72701
Sechang Oh
Department of Electrical Engineering,
University of Arkansas
, Fayetteville, AR 72701
Hyeokjun Kwon
Department of Electrical Engineering,
University of Arkansas
, Fayetteville, AR 72701
Phillip Hankins
Department of Electrical Engineering,
University of Arkansas
, Fayetteville, AR 72701J. Nanotechnol. Eng. Med. Aug 2010, 1(3): 031012 (11 pages)
Published Online: August 27, 2010
Article history
Received:
June 25, 2010
Revised:
June 29, 2010
Published:
August 27, 2010
Citation
Varadan, V. K., Oh, S., Kwon, H., and Hankins, P. (August 27, 2010). "Wireless Point-of-Care Diagnosis for Sleep Disorder With Dry Nanowire Electrodes." ASME. J. Nanotechnol. Eng. Med. August 2010; 1(3): 031012. https://doi.org/10.1115/1.4002138
Download citation file:
Get Email Alerts
Cited By
DNA-Based Bulk Hydrogel Materials and Biomedical Application
J. Nanotechnol. Eng. Med (November 2015)
Transient Low-Temperature Effects on Propidium Iodide Uptake in Lance Array Nanoinjected HeLa Cells
J. Nanotechnol. Eng. Med (November 2015)
Engineering Embryonic Stem Cell Microenvironments for Tailored Cellular Differentiation
J. Nanotechnol. Eng. Med (November 2015)
Related Articles
An Approach to Seizure Onset Detection Using Fuzzy Logic Based on Seizure Evolution in Intracranial EEG
J. Med. Devices (June,2011)
Home Telemedicine: Encryption is Not Enough
J. Med. Devices (June,2009)
High-Density Transcranial Direct Current Stimulation (HD-tDCS): Hardware Interface
J. Med. Devices (June,2009)
Heterostructured IrO 2 / Au Nanowire Electrodes and Unit Recordings From Hippocampal Rat Brain
J. Nanotechnol. Eng. Med (May,2010)
Related Proceedings Papers
Related Chapters
Feature Extraction and Classification of EEG Signal
International Conference on Mechanical Engineering and Technology (ICMET-London 2011)
Classifying EEG-Based Motor Imagery Tasks by Means of Wavelet Packet and Sample Entropy
International Conference on Instrumentation, Measurement, Circuits and Systems (ICIMCS 2011)
A Review of Most Current Feature Extraction Methods for EEG Signal Processing
International Conference on Computer and Automation Engineering, 4th (ICCAE 2012)