Abstract

This paper deals with ultrasonic imaging in a nondestructive evaluation (NDE) context. In particular, we are focused on the inspection of coarse-grained steels having a heterogeneous composition that creates structural noise in the ultrasonic signals and images. The standard way to beamform the acquired ultrasonic data is by delay-and-sum (DAS). This method is fast but suffers from low signal-to-noise ratio (SNR) for coarse-grained steel inspection. In this paper, we propose to adapt a coherence-based beamformer called pDAS from the medical imaging community. pDAS beamforming is based on DAS structure but includes p-root and p-power before and after summations, respectively. It results in an enhancement of the coherent summation of signals that improves both resolution and contrast. Coherence-based beamformers are known to enhance information whose acoustic response correlates with geometrical information, that is why they decrease grating lobes and side lobes, specular echoes, reconstruction artifacts, and noise due to multiple scattering. In this paper, the pDAS beamformer is proposed for two common acquisition schemes employed in NDE that are plane wave imaging (PWI) and full matrix capture (FMC). The beamformers have been efficiently implemented for parallel computing on graphics processing unit (GPU) in a context of real-time imaging and fast part scanning in NDE. First, experimental results are presented from an austenitic-ferritic sample from the power generation industry that contains side drilled holes (SDH) with diameter 0.4 mm at several depths. pDAS (for p from two to three) shows improvements in terms of SNR and resolution compared to standard DAS, both in PWI and FMC modalities. We also show that the computation cost of pDAS is equivalent to DAS. A real application on a sample containing a fatigue crack connected to the backwall is exposed. We show that pDAS beamformer can enhance crack response compared to grains, but it also decreases unwanted information such as backwall specular echoes and reconstruction artifacts.

References

1.
Papadakis
,
E. P.
,
1965
, “
Ultrasonic Attenuation Caused by Scattering in Polycrystalline Metals
,”
J. Acoust. Soc. Am.
,
37
(
4
), pp.
711
717
.
2.
Laroche
,
N.
,
Bourguignon
,
S.
,
Carcreff
,
E.
,
Idier
,
J.
, and
Duclos
,
A.
,
2020
, “
An Inverse Approach for Ultrasonic Imaging From Full Matrix Capture Data: Application to Resolution Enhancement in NDT
,”
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
,
67
(
9
), pp.
1877
1887
.
3.
Perrot
,
V.
,
Polichetti
,
M.
,
Varray
,
F.
, and
Garcia
,
D.
,
2021
, “
So You Think You Can DAS? A Viewpoint on Delay-and-Sum Beamforming
,”
Ultrasonics
,
111
, p.
106309
.
4.
Montaldo
,
G.
,
Tanter
,
M.
,
Bercoff
,
J.
,
Benech
,
N.
, and
Fink
,
M.
,
2009
, “
Coherent Plane-Wave Compounding for Very High Frame Rate Ultrasonography and Transient Elastography
,”
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
,
56
(
3
), pp.
489
506
.
5.
Chiao
,
R.
, and
Thomas
,
L.
,
1994
, “
Analytic Evaluation of Sampled Aperture Ultrasonic Imaging Techniques for NDE
,”
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
,
41
(
4
), pp.
484
493
.
6.
Karaman
,
M.
,
Li
,
P.-C.
, and
O’Donnell
,
M.
,
1995
, “
Synthetic Aperture Imaging for Small Scale Systems
,”
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
,
42
(
3
), pp.
429
442
.
7.
Holmes
,
C.
,
Drinkwater
,
B. W.
, and
Wilcox
,
P. D.
,
2005
, “
Post-Processing of the Full Matrix of Ultrasonic Transmit-Receive Array Data for Non-Destructive Evaluation
,”
NDT E Int.
,
38
(
8
), pp.
701
711
.
8.
Bae
,
M.-H.
, and
Jeong
,
M.-K.
,
2000
, “
A Study of Synthetic-Aperture Imaging With Virtual Source Elements in B-Mode Ultrasound Imaging Systems
,”
IEEE Trans. Ultrason., Ferroelectr. Freq. Control
,
47
(
6
), pp.
1510
1519
.
9.
Shahjahan
,
S.
,
Aubry
,
A.
,
Rupin
,
F.
,
Chassignole
,
B.
, and
Derode
,
A.
,
2014
, “
A Random Matrix Approach to Detect Defects in a Strongly Scattering Polycrystal: How the Memory Effect Can Help Overcome Multiple Scattering
,”
Appl. Phys. Lett.
,
104
(
23
), p.
234105
.
10.
Lopez Villaverde
,
E.
,
Robert
,
S.
, and
Prada
,
C.
,
2016
, “
Ultrasonic Imaging of Defects in Coarse-grained Steels With the Decomposition of the Time Reversal Operator
,”
J. Acoust. Soc. Am.
,
140
(
1
), pp.
541
550
.
11.
Mallart
,
R.
, and
Fink
,
M.
,
1994
, “
Adaptive Focusing in Scattering Media Through Sound Speed Inhomogeneities: The Van Cittert Zernike Approach and Focusing Criterion
,”
J. Acoust. Soc. Am.
,
96
(
6
), pp.
3721
3732
.
12.
Li
,
P.-C.
, and
Li
,
M.-L.
,
2003
, “
Adaptive Imaging Using the Generalized Coherence Factor
,”
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
,
50
(
2
), pp.
128
141
.
13.
Camacho
,
J.
,
Parrilla
,
M.
, and
Fritsch
,
C.
,
2009
, “
Phase Coherence Imaging
,”
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
,
56
(
5
), pp.
958
974
.
14.
Camacho
,
J.
, and
Fritsch
,
C.
,
2011
, “
Phase Coherence Imaging of Grained Materials
,”
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
,
58
(
5
), pp.
1006
1015
.
15.
Cruza
,
J.
,
Camacho
,
J.
, and
Fritsch
,
C.
,
2017
, “
Plane-Wave Phase-Coherence Imaging for NDE
,”
NDT E Int.
,
87
, pp.
31
37
.
16.
Baiotto
,
R.
,
Knight-Gregson
,
B.
,
Nageswaran
,
C.
, and
Clarke
,
T.
,
2018
, “
Coherence Weighting Applied to FMC/TFM Data From Austenitic Cra Clad Lined Pipes
,”
J. Nondestr. Eval.
,
37
(
49
).
17.
Dupont-Marillia
,
F.
,
Krynicki
,
J. W.
, and
Bélanger
,
P.
,
2022
, “
Early Detection of High Temperature Hydrogen Attack Using the Ultrasonic Full Matrix Capture and Advanced Post-Processing Methods
,”
NDT E Int.
,
130
, p.
102676
.
18.
Gauthier
,
B.
,
Painchaud-April
,
G.
,
Le Duff
,
A.
, and
Bélanger
,
P.
,
2021
, “
Towards an Alternative to Time of Flight Diffraction Using Instantaneous Phase Coherence Imaging for Characterization of Crack-Like Defects
,”
Sensors
,
21
(
3
).
19.
Matrone
,
G.
,
Savoia
,
A. S.
,
Caliano
,
G.
, and
Magenes
,
G.
,
2015
, “
The Delay Multiply and Sum Beamforming Algorithm in Ultrasound B-Mode Medical Imaging
,”
IEEE Trans. Med. Imaging
,
34
(
4
), pp.
940
949
.
20.
Matrone
,
G.
,
Ramalli
,
A.
,
Savoia
,
A. S.
,
Tortoli
,
P.
, and
Magenes
,
G.
,
2017
, “
High Frame-Rate, High Resolution Ultrasound Imaging With Multi-line Transmission and Filtered-delay Multiply and Sum Beamforming
,”
IEEE Trans. Med. Imaging
,
36
(
2
), pp.
478
486
.
21.
Teng
,
D.
,
Liu
,
L.
,
Xiang
,
Y.
, and
Xuan
,
F.-Z.
,
2023
, “
An Optimized Total Focusing Method Based on Delay-Multiply-and-Sum for Nondestructive Testing
,”
Ultrasonics
,
128
, p.
106881
.
22.
Polichetti
,
M.
,
Varray
,
F.
,
Béra
,
J.-C.
,
Cachard
,
C.
, and
Nicolas
,
B.
,
2018
, “
A Nonlinear Beamformer Based on P-th Root Compression – Application to Plane Wave Ultrasound Imaging
,”
Appl. Sci.
,
8
(
4
).
23.
Shen
,
C.-C.
, and
Hsieh
,
P.-Y.
,
2019
, “
Two-Dimensional Spatial Coherence for Ultrasonic DMAS Beamforming in Multi-angle Plane-Wave Imaging
,”
Appl. Sci.
,
9
(
19
).
24.
Matrone
,
G.
,
Ramalli
,
A.
,
DHooge
,
J.
,
Tortoli
,
P.
, and
Magenes
,
G.
,
2020
, “
A Comparison of Coherence-Based Beamforming Techniques in High-Frame-Rate Ultrasound Imaging With Multi-line Transmission
,”
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
,
67
(
2
), pp.
329
340
.
25.
Camacho
,
J.
,
Parilla
,
M.
, and
Fritsch
,
C.
,
2009
, “
Grating-Lobes Reduction by Application of Phase Coherence Factors
,”
2009 IEEE International Ultrasonics Symposium (IUS)
,
Roma, Italy
,
Sept. 20–23.
26.
Camacho
,
J.
,
Atehortua
,
D.
,
Cruza
,
J.-F.
,
Brizuela
,
J.
, and
Ealo
,
J.
,
2018
, “
Ultrasonic Crack Evaluation by Phase Coherence Processing and TFM and Its Application to Online Monitoring in Fatigue Tests
,”
NDT E Int.
,
93
, pp.
164
174
.
27.
Sutcliffe
,
M.
,
Weston
,
M.
,
Dutton
,
B.
,
Charlton
,
P.
, and
Donne
,
K.
,
2012
, “
Real-Time Full Matrix Capture for Ultrasonic Non-Destructive Testing With Acceleration of Post-Processing Through Graphic Hardware
,”
NDT E Int.
,
51
, pp.
16
23
.
28.
Zhang
,
J.
,
Drinkwater
,
B. W.
,
Wilcox
,
P. D.
, and
Hunter
,
A. J.
,
2010
, “
Defect Detection Using Ultrasonic Arrays: The Multi-mode Total Focusing Method
,”
NDT E Int.
,
43
(
2
), pp.
123
133
.
29.
Zhang
,
J.
,
Drinkwater
,
B. W.
, and
Wilcox
,
P. D.
,
2014
, “
Efficient Immersion Imaging of Components With Nonplanar Surfaces
,”
IEEE Trans. Ultrason. Ferroelectr. Freq. Control
,
61
(
8
), pp.
1284
1295
.
You do not currently have access to this content.