The United States Department of Energy's Savannah River Site (SRS) in Aiken, South Carolina, is dedicated to promoting site-level, risk-based inspection practices to maintain a safe and productive work environment. Protective suits are worn by personnel working in contaminated environments. These suits require that cooling be applied to keep the interior temperature within safe and comfortable limits. A vortex tube, also known as the Ranque-Hilsch vortex tube (RHVT), can provide the necessary cooling. As mechanical devices void of moving components, vortex tubes separate a compressed gas into hot and cold streams—the air emerging from the “hot” end reaching a temperature of 433.2 K and the air emerging from the “cold” end reaching a temperature of 241.5 K (Hilsch, 1946, “Die Expansion Von Gasen Im Zentrifugalfeld Als Kälteprozeß,” Z. Für Naturforsch., 1, pp. 208–214). Routing the cold stream of the vortex tube to the user's protective suit facilitates the required cooling. Vortex tubes currently in use at SRS are preset, through modification solely by and within the SRS respiratory equipment facility (REF), to provide a temperature reduction between 22.2 and 25.0 K. When a new model of vortex tube capable of user adjustment during operation recently became available, prototype testing was conducted for product comparison. Ultimately, it was identified that similar cooling performance between the old and new models is achievable. Production units were acquired to be subjected to complete product analysis at SRS utilizing a statistical test plan. The statistical test plan, data, thermodynamic calculations, and conclusions were reviewed to determine acceptability for site use.

References

1.
Hilsch
,
R.
,
1946
, “
Die Expansion Von Gasen Im Zentrifugalfeld Als Kälteprozeß
,”
Z. Für Naturforsch.
,
1
, pp.
208
214
.
2.
Baker
,
P. S.
, and
Rathkamp
,
W. R.
,
1956
, “
Investigations on the Ranque-Hilsch (Vortex) Tube
,” Oak Ridge National Laboratory, U.S. Atomic Energy Commission, Oak Ridge, TN, Report No. ORNL-1659.
3.
Xue
,
Y.
,
Arjomandi
,
M.
, and
Kelso
,
R.
,
2013
, “
The Working Principle of a Vortex Tube
,”
Int. J. Refrig.
,
36
(
6
), pp.
1730
1740
.
4.
ANSI/ASQ Z1.4-2003 (R 2013)
,
2013
, “
Sampling Procedures and Tables for Inspection by Attributes
,” American National Standards Institute/American Society for Quality, Tables X-H—Tables for sample size code letter: H, pp. 45–46.
5.
Simoes-Moreira
,
J. R.
,
2010
, “
An Air-Standard Cycle and a Thermodynamic Perspective on Operational Limits of Ranque-Hilsch or Vortex Tubes
,”
Int. J. Refrig.
,
33
(
4
), pp.
765
773
.
6.
OSHA Regulations (Standards – 29 CFR)
, Part
1926
, 2017, “
Safety and Health Regulations for Construction
,” Occupational Safety and Health Administration, Washington, DC, pp. 35–36.
7.
NIOSH
, June
1998
, “
Criteria for a Recommended Standard: Occupational Noise Exposure, Revised Criteria 1998
,” National Institute for Occupational Safety and Health, Washington, DC, p. 24.
8.
United States Nuclear Regulatory Commission (U.S.NRC) Regulations (Standards – 10 CFR), Part 20, 2017, “
Standards for Protection against Radiation
,” p. 344, 365.
9.
SAS Institute,
2014
, “JMP™ Pro”, Version 11.2.1, SAS Institute, Cary, NC.
10.
Conover
,
W. J.
,
1980
,
Practical Nonparametric Statistics
, 2nd ed.,
Wiley
,
New York
.
11.
Taylor Enterprises,
2007
,
Distribution Analyzer
, Version 1.2,
Taylor Enterprises
,
Libertyville, IL
.
12.
D'Agostino
,
R. B.
, and
Stephens
,
M. A.
,
1986
,
Goodness of Fit Techniques
,
Marcel Dekker
,
New York
.
13.
Figliola
,
R. S.
, and
Beasley
,
D. E.
,
2011
,
Theory and Design for Mechanical Measurements
, 5th ed.,
Wiley
,
New York
, p.
164
, 170, 184, 190–192.
14.
Moran
,
M. J.
,
Shapiro
,
H. N.
,
Boettner
,
D. D.
, and
Bailey
,
M. B.
,
2011
,
Fundamentals of Engineering Thermodynamics
, 7th ed.,
Wiley
,
New York
, p.
925
.
15.
Vining
,
G.
, and
Kowalski
,
S. M.
,
2011
,
Statistical Methods for Engineers
, 3rd ed.,
Brooks/Cole
,
Boston, MA
, p.
595
.
You do not currently have access to this content.