The efficient operation of a solar cooling system strongly depends on the chiller behavior under part load conditions, since driving energy and cooling load are never constant. For this reason, the performance of a single stage, hot water driven 30 kW H2O/LiBr-absorption chiller employed in a solar cooling system with a field of 350m2 evacuated tube collector has been analyzed under part load conditions with both simulations and experiments. A simulation model has been developed for the whole absorption chiller (Type Yazaki WFC-10), where all internal mass and energy balances are solved. The connection to the external heat reservoirs of hot, chilled, and cooling water is done by lumped and distributed UA values for the main heat exchangers. In addition to an analytical evaporator model—which is described in detail—experimental correlations for UA values have been used for the condenser, generator, and solution heat exchanger. For the absorber, a basic model based on the Nusselt theory has been employed. The evaporator model was developed, taking into account the distribution of refrigerant on the tube bundle, as well as the change in operation from a partially dry to an overflowing evaporator. A linear model is derived to calculate the wetted area. The influence of these effects on cooling capacity and coefficient of performance (COP) is calculated for three different combinations of hot and cooling water temperature. The comparison to experimental data shows a good agreement in the various operational modes of the evaporator. The model is able to predict the transition from partially dry to an overflowing evaporator quite well. The present deviations in the domain with high refrigerant overflow can be attributed to the simple absorber model and the linear wetted area model. Nevertheless, the results of this investigation can be used to improve control strategies for new and existing solar cooling systems.

1.
Albers
,
J.
, and
Ziegler
,
F.
, 2003, “
Analysis of the Part Load Behaviour of Sorption Chillers With Thermally Driven Solution Pumps
,”
Proceedings of the 21st International Congress of Refrigeration
, IIR/IIF, WA, Paper No. ICR0570.
2.
Albers
,
J.
,
Ziegler
,
F.
, and
Asdrubali
,
F.
, 2005, “
Investigation Into the Influence of the Cooling Water Temperature on the Operating Conditions of Thermosyphon Generators
,”
Proceedings of the International Sorption Heat Pump Conference
, Denver, CO, June 22–24, Paper No. ISHPC-053-2005.
3.
Kruse
,
C. -D.
, 1999, “
Berichtsteil II: Simulation und experimentelle Identifikation des Betriebsverhaltens von kleinen heißwasserbetriebenen Absorptionskältemaschinen
,”
TU Dresden
, Institut für Energietechnik und Fernwärme-Forschungsinstitut, Hannover eV, Koordinierter Schlussbericht AiF Fördernummer 11259 B.
4.
Petukhov
,
B. S.
, 1970,
Advances in Heat Transfer
,
T. F.
Irvine
and
J. P.
Hartnett
, eds., Vol.
6
,
Academic
,
New York
.
5.
Hu
,
X.
, and
Jacobi
,
A. M.
, 1996, “
‘The Intertube Falling Film: Part 1—Flow Characteristics, Mode Transitions and Hysteresis
,”
ASME J. Heat Transfer
0022-1481,
118
, pp.
616
625
.
6.
Liu
,
Z.
, and
Yi
,
J.
, 2002, “
Falling Film Evaporation Heat Transfer of Water/Salt Mixtures From Roll Worked Enhanced Tubes and Tube Bundle
,”
Appl. Therm. Eng.
1359-4311,
22
, pp.
83
95
.
7.
Francés
,
V. M. S.
, and
Ojer
,
J. M. P.
, 2003, “
Validation of a Model for the Absorption Process of H2O(vap) by a LiBr(aq) in a Horizontal Tube Bundle, Using a Multi-Factorial Analysis
,”
Int. J. Heat Mass Transfer
0017-9310,
46
, pp.
3299
3312
.
8.
Kim
,
J.
,
Park
,
C. W.
, and
Kang
,
Y. T.
, 2003, “
The Effect of Microsurface Treatment on Heat and Mass Transfer Performance for a Falling Film H2O/LiBr Absorber
,”
Int. J. Refrig.
0140-7007,
26
, pp.
575
585
.
9.
Hellmann
,
H. -M.
,
Schweigler
,
C.
, and
Ziegler
,
F.
, 1999, “
The Characteristic Equation of Sorption Chillers
,”
Proceedings of the International Sorption Heat Pump Conference (ISHPC 99)
, Munich, Germany, March 24–26, pp.
169
172
.
10.
Hellmann
,
H. -M.
,
Schweigler
,
C.
, and
Ziegler
,
F.
, 1998, “
A Simple Method for Modeling the Operating Characteristics of Absorption Chillers
,”
Proceedings of the Eurotherm Seminar No.59
, Nancy-Ville, France, Vols.
6–7
, pp.
219
226
.
11.
Grossman
,
G.
, and
Michelson
,
E.
, 1985, “
A Modular Computer Simulation of Absorption Systems
,”
ASHRAE Trans.
0001-2505,
91
, Part 2B, pp.
1808
1827
.
12.
Asdrubali
,
F.
, and
Grignaffini
,
S.
, 2005, “
Experimental Evaluation of the Performances of a H2O–LiBr Absorption Refrigerator Under Different Service Conditions
,”
Int. J. Refrig.
0140-7007,
28
, pp.
489
497
.
13.
Li
,
Z. F.
, and
Sumathy
,
K.
, 2001, “
Simulation of a Solar Absorption Air Conditioning System
,”
Energy Convers. Manage.
0196-8904,
42
, pp.
313
327
.
14.
Klein
,
S. A.
, and
Alvardo
,
R. L.
, 1990,
EES: Engineering Equation Solver
,
F-Chart Software
,
Middleton, WI
.
You do not currently have access to this content.